Parker´s bearing isolator selection includes non-contact, labyrinth designs which provide unsurpassed bearing protection for rotary shaft equipment. It is designed to retain lubrication and exclude aggressive contaminants in non-flooded applications. Specialty isolators include dual-contacting versions for flooded and oil mist applications, among many others.
Operation Type: Non-Flooded
Maximum Surface Speed: Up to 5,000 fpm (25 m/s)
Pressure Rating: 0 psi
Axial Movement: 0.020 inch (0.51 mm)
Eccentricity: 0.020 inch (0.51 mm)
Operating Temperature: -40 to 250 °F / -40 to 121 °C
Due to the customized nature of this product, only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from 1/2” to 10” (12 mm to 254 mm). For a list of common sizes see Product Support tab.
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly. By keeping lubrication in and contaminants out, Parker’s ProTech bearing isolators provide reliable, two-way sealing protection of rotating equipment for extended bearing life. Labyrinth sealing technology applied to high performance materials allows the Parker ProTech™ LS Profile bearing isolator to operate far beyond the shaft speed limits of standard radial lip seals and avoids shaft wear. Because it is a precision-machined seal, costs can be eliminated on tooling charges, allowing retrofit of most shaft and bore combinations.
The non-contact design has virtually no torque consumption, will not wear or groove shafts, and allows for non-lubricated dry running. It also accommodates the greatest axial movement in the industry, reducing a major factor that causes labyrinth seal failure.
We can custom engineer solutions to meet exacting specifications for either new or retrofit applications. When used to replace lip seals, the LS Profile lowers shaft cost due to liberal surface finish specifications.
DESIGN
An external O-ring on the outside diameter of the ProTech stator allows for easy seal installation, maintains a press fit in the seal housing, and provides a static seal against the bore for lubricant retention. The stator has a sophisticated series of grooves to retain oil splash, the most effective design for oil retention when compared to various competitor designs.
The rotor uses an external O-ring to maintain a static press fit on the shaft. Since the rotor spins with the shaft, it will not wear, groove, or damage the shaft. This eliminates costs associated with having to recondition the sealing surface of the shaft.
The rotor and stator are assembled at Parker’s factory where they are permanently unitized, allowing for a one-piece installation. This unitized design also maintains the seal’s integrity by keeping high-pressure water spray, vibration or axial movement from separating or increasing the gap between the rotor and stator.
APPLICATIONS
The LS profile is our standard design for non-flooded applications. It is ideal for sealing and protecting the bearing housings of electric motors, pumps, mixers, gear boxes, blowers and custom equipment against heavy water spray and dry contaminants. The flange seats against the housing and acts as an installation guide by ensuring the seal alignment is correct. The LS design is excellent for retaining grease and oil splash, however the oil level must be below the inboard oil drainback (non-flooded).
Maximum internal pressure: 0 psi (0 bar)
The LS Profile shaft mounting positions and respective compatible lubrication types are:
MATERIALS
Stator & Rotor: ProTech uses proprietary PTFE compounds making it well suited for harsh environments, such as citric acids and strong caustics. This superior chemical resistance allows for the standardization of a single material within a plant, eliminating the cost associated with stocking duplicate sizes in expensive stainless steel or other exotic materials. Standard chemical compatibility charts recommend PTFE for 160 chemicals in comparison to 11 for bronze and 30 for stainless steel.
Characteristics of the various PTFE materials offered:
O-Rings: Come standard as FKM, but are also available in:
SIZE RANGE
Parker manufactures the LS Profile in standard shaft diameters ranging from 1/2” to 10” (12.7 mm to 254 mm). Because this is a precision machined seal, we can manufacture virtually any configuration.
Operation Type: Non-Flooded
Maximum Surface Speed: Up to 5,000 fpm (25 m/s)
Pressure Rating: 0 psi
Axial Movement: 0.020 inch (0.51 mm)
Eccentricity: 0.020 inch (0.51 mm)
Operating Temperature: -40° to 250 °F / -40° to 121 °C
Shaft Diameter: 0.500 to 10.000 inch (12 to 250 mm)
Bore Diameter: 1.250 to 11.500 inch (26 to 290 mm)
Seal Material: PTFE
O-Ring Material: FKM is standard. Alternates available
Only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from 1/2” to 10” (12.7 mm to 250 mm). For a list of common sizes see Product Support tab.
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly. By keeping lubrication in and contaminants out, Parker’s ProTech™ bearing isolators provide reliable, two-way sealing protection of rotating equipment for extended bearing life. Labyrinth sealing technology applied to high performance materials allows the Parker ProTech LN Profile bearing isolator to operate far beyond the shaft speed limits of standard radial lip seals and avoids shaft wear. Because it is a precision-machined seal, costs can be eliminated on tooling charges, allowing retrofit of most shaft and bore combinations.
The non-contact design has virtually no torque consumption, will not wear or groove shafts, and allows for non-lubricated dry running. It also accommodates the greatest axial movement in the industry, reducing a major factor that causes labyrinth seal failure.
We can custom engineer solutions to meet exacting specifications for either new or retrofit applications. When used to replace lip seals, the LN Profile lowers shaft cost due to liberal surface finish specifications.
DESIGN
An external O-ring on the outside diameter of the ProTech stator allows for easy seal installation, maintains a press fit in the seal housing, and provides a static seal against the bore for lubricant retention. The stator has a sophisticated series of grooves to retain oil splash, the most effective design for oil retention when compared to various competitor designs.
The rotor uses an external O-ring to maintain a static press fit on the shaft. Since the rotor spins with the shaft, it will not wear, groove, or damage the shaft. This eliminates costs associated with having to recondition the sealing surface of the shaft.
The rotor and stator are assembled at Parker’s factory where they are permanently unitized, allowing for a one-piece installation. This unitized design also maintains the seal’s integrity by keeping high-pressure water spray, vibration or axial movement from separating or increasing the gap between the rotor and stator.
APPLICATIONS
The LN profile is our standard design for non-flooded applications where the seal must be mounted flush in the housing. It is ideal for sealing and protecting the bearing housings of electric motors, pumps, mixers, gear boxes, blowers and custom equipment against heavy water spray and dry contaminants. The LN design is excellent for retaining grease and oil splash, however the oil level must be below the inboard oil drainback (non-flooded).
Maximum internal pressure: 0 psi (0 bar)
The LN Profile shaft mounting positions and respective compatible lubrication types are:
MATERIALS
Stator & Rotor: ProTech uses, proprietary PTFE compounds making it well suited for harsh environments, such as citric acids and strong caustics. This superior chemical resistance allows for the standardization of a single material within a plant, eliminating the cost associated with stocking duplicate sizes in expensive stainless steel or other exotic materials. Standard chemical compatibility charts recommend PTFE for 160 chemicals in comparison to 11 for bronze and 30 for stainless steel.
Characteristics of the various PTFE materials offered:
O-Rings: Come standard as FKM, but are also available in:
SIZE RANGE
Parker manufactures the LN Profile in standard shaft diameters ranging from 1/2” to 10” (12.7mm to 250mm). Because this is a precision machined seal, we can manufacture virtually any configuration.
Operation Type: Flooded
Maximum Surface Speed: Up to 3,000 fpm (15 m/s)
Pressure Rating: 5 psi
Axial Movement: 0.003 inch (0.08 mm)
Eccentricity: 0.003 inch (0.08 mm)
Operating Temperature: -40° to 250 °F / -40° to 121 °C
Shaft Diameter: 0.500 to 10.000 inch (13 to 250 mm)
Bore Diameter: 1.250 to 11.500 inch (32 to 290 mm)
Seal Material: PTFE and SS Sleeve
O-Ring Material: FKM is standard. Alternates available
Due to the customized nature of this product, only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from 1/2” to 10” (13mm to 254mm). For a list of common sizes see Product Support tab.
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly. By keeping lubrication in and contaminants out, Parker’s ProTech™ bearing isolators provide reliable, two-way sealing protection of rotating equipment for extended bearing life and zero shaft wear. Labyrinth sealing technology applied to high performance materials allows the ProTech FS-360 bearing isolator to operate far beyond shaft speed limits of standard radial lip seals.
Because it is a precision-machined seal, costs can be eliminated on tooling charges, allowing retrofit of most shaft and bore combinations.
DESIGN
An external O-ring on the outside diameter of the ProTech stator allows for easy seal installation, maintains a press fit in the seal housing, and provides a static seal against the bore for oil retention. The stator features PTFE lips which ride on an internal stainless steel sleeve for zero shaft wear. The rotor utilizes dual O-rings to maintain a static press fit on the shaft. Since the rotor spins with the shaft, it will not wear, groove, or damage the shaft. This eliminates costs associated with having to recondition the sealing surface of the shaft.
The rotor and stator are assembled at the Parker facility where they are permanently unitized, allowing for a one-piece installation. This unitized design also maintains the seal’s integrity by keeping high-pressure water spray, vibration or axial movement from separating or increasing the gap between the rotor and stator.
APPLICATIONS
The FS 360 design is specifically designed for flooded oil level and oil mist applications and for applications that may require an airtight seal. The flange seats against the housing and acts as an installation guide by ensuring the seal alignment is correct. It is ideal for equipment used in food processing or subjected to frequent wash down where positive oil retention is required. It is also used for severe splash exclusion for gearboxes, motors, pumps, mixers, cooling towers, aerators, and custom equipment. If external contamination is heavy in vertical up mounting position, contact Parker for assistance.
Total Eccentricity: 0.003” (0.08 mm)
Shaft Speed: Up to 3,000 fpm (15 m/s). Contact factory for speed exceeding 3,000 fpm (15 m/s).
Axial Movement: 0.003” (0.08 mm)
Maximum internal pressure: 5 psi (0.34 bar)
Shaft/Bore Tolerances: ±0.002” (±0.05 mm). Special designs available.
MATERIALS
Stator: ProTech uses proprietary PTFE compounds making it well suited for harsh environments.
Characteristics of the various PTFE materials offered:
Rotor: The 360 series utilizes stainless steel for the rotor. This provides excellent corrosion resistance and chemical compatibility, as well as the ability to transition well into FDA applications. It is highly resistant to the attack of marine and corrosive industrial atmospheres as well as acids, dyes and salts.
O-Rings: Come standard as FKM, but also available in:
SIZE RANGE
Parker manufactures the FS-360 Profile in standard shaft diameters ranging from 1/2” to 10” (13mm to 254mm). Because this is a precision machined seal, we can manufacture virtually any configuration.
Operation Type: Non-Flooded
Maximum Surface Speed: Up to 5,000 fpm (25 m/s)
Pressure Rating: 0 psi
Axial Movement: 0.020 inch (0.51 mm)
Eccentricity: 0.020 inch (0.51 mm)e
Operating Temperature: -40° to 250 °F / -40° to 121 °C
Shaft Diameter: 0.492 to 10.000 inch (12.5 to 254 mm)
Bore Diameter: 0.886 to 11.575 inch (22.5 to 294 mm)
Seal Material: PTFE
O-Ring Material: FKM is standard. Alternates availabl
Due to the customized nature of this product, only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from 0.492” to 10” (12.5 mm to 254 mm). For a list of common sizes see Product Support tab.
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly. By keeping lubrication in and contaminants out, Parker’s ProTech™ bearing isolators provide reliable, two-way sealing protection of rotating equipment for extended bearing life. Labyrinth sealing technology applied to high performance materials allows the Parker ProTech LW Profile bearing isolator to operate far beyond the shaft speed limits of standard radial lip seals and avoids shaft wear. Because it is a precision-machined seal, costs can be eliminated on tooling charges, allowing retrofit of most shaft and bore combinations.
The non-contact design has virtually no torque consumption, will not wear or groove shafts, and allows for non-lubricated dry running. It also accommodates the greatest axial movement in the industry, reducing a major factor that causes labyrinth seal failure.
We can custom engineer solutions to meet exacting specifications for either new or retrofit applications. When used to replace seals during planned or unplanned rebuilds, the LW Profile lowers shaft cost due to liberal surface finish specifications.
DESIGN
The LW Profile with its wrap-around geometry and enhanced rotor design features a more robust and aggressive labyrinth profile over standard designs. Enhanced drainback and internal oil splash grooves manage heavy oil splash in the bearing cavity. An external O-ring on the outside diameter of the ProTech stator allows for easy seal installation, maintains a press fit in the seal housing, and provides a static seal against the bore for lubricant retention. The stator has a sophisticated series of grooves to retain oil splash, the most effective design for oil retention when compared to various competitor designs.
The rotor uses an external O-ring to maintain a static press fit on the shaft. Since the rotor spins with the shaft, it will not wear, groove, or damage the shaft. This eliminates costs associated with having to recondition the sealing surface of the shaft.
The rotor and stator are assembled at Parker’s factory where they are permanently unitized, allowing for a one-piece installation. This unitized design also maintains the seal’s integrity by keeping high-pressure water spray, vibration or axial movement from separating or increasing the gap between the rotor and stator.
APPLICATIONS
The LW profile is an enhanced design for applications with aggressive oil splash and heavy contamination. It is ideal for sealing and protecting the bearing housings of electric motors, pumps, mixers, gear boxes, blowers and custom equipment against heavy water spray and dry contaminants. The flange seats against the housing and acts as an installation guide by ensuring the seal alignment is correct.
The LW design is excellent for retaining grease and oil splash, however the oil level must be below the inboard oil drainback (non-flooded). The LW Profile is recommended over alternate profiles where contamination is heavy, but is not compatible with oil lubricated vertical down systems.
Total Eccentricity: 0.020” (0.51 mm)
Shaft speed: Up to 3,000 fpm (15 m/s). Contact Parker for speeds >3,000 fpm (15 m/s).
Maximum internal pressure: 0 psi (0 bar)
Axial Movement: 0.020” (0.51 mm) Special designs up to 0.070” (1.78 mm)
Shaft/Bore: Tolerances: ±0.002” (±0.0 5mm)
The LW Profile shaft mounting positions and respective compatible lubrication types are:
MATERIALS
Stator & Rotor: ProTech uses proprietary PTFE compounds making it well suited for harsh environments, such as citric acids and strong caustics. This superior chemical resistance allows for the standardization of a single material within a plant, eliminating the cost associated with stocking duplicate sizes in expensive stainless steel or other exotic materials.
Characteristics of the various PTFE materials offered:
O-Rings: Come standard as FKM, but are also available in:
SIZE RANGE
Parker manufactures the LW Profile in standard shaft diameters ranging from 0.492” to 10” (12.5 mm to 254 mm). Because this is a precision machined seal, we can manufacture virtually any configuration.
Operation Type: Non-Flooded
Maximum Surface Speed: Up to 5,000 fpm (25 m/s)
Pressure Rating: 0 psi
Axial Movement: 0.020 inch (0.51 mm)
Eccentricity: 0.020 inch
Operating Temperature: -40° to 250 °F / -40° to 121 °C
Shaft Diameter: 0.500 to 10.000 inch (12 to 254 mm)
Bore Diameter: 1.125 to 11.500 inch (22 to 294 mm)
Seal Material: PTFE
O-Ring Material: FKM is standard. Alternates available
Due to the customized nature of this product, only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from ½” to 10” (12mm to 254mm).
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly. By keeping lubrication in and contaminants out, Parker’s ProTech™ bearing isolators provide reliable, two-way sealing protection of rotating equipment for extended bearing life. Labyrinth sealing technology applied to high performance materials allows Parker’s ProTech LP Profile bearing isolator to operate far beyond shaft speed limits of standard radial lip seals and avoid shaft wear.
Our non-contact design has virtually no torque consumption and therefore will not wear or groove shafts, and allows for non-lubricated dry runs. It also accommodates the greatest axial movement in the industry,reducing a major factor that causes labyrinth seal failure.
We can custom engineer solutions to meet exacting specifications for either new or retrofit applications. When used to replace seals during planned or unplanned rebuilds, the LP Profile lowers shaft cost due to liberal specifications. Costs can also be eliminated on tooling charges due to the fact that ProTech is a precision-machined seal.
Many LP’s have a labyrinth design like our ProTech LS Profile. However, the LP designation may also refer to a stator-only design for niche applications. Contact Parker regarding the LP Profile.
DESIGN
Parker can configure custom bearing isolator designs to fit most applications. These isolators range from small and simple to large and complex. For example, but not limited to:
MATERIALS
ProTech uses proprietary PTFE compounds making it well suited for harsh environments, such as citric acids and strong caustics. This superior chemical resistance allows for the standardization of a single material within a plant, eliminating the need to stock duplicate sizes in expensive stainless steel or other exotic materials.
Characteristics of the various PTFE materials offered:
O-Rings: Come standard as FKM, but are also available in:
Shaft mounting position and compatible lubrication types:
Horizontal Mounting: Grease, Oil, Dry
Vertical Up Mounting: Grease, Oil, Dry (If contaminant level is heavy see LW design)
Vertical Down Mounting: Grease, Dry
SIZE RANGE
Parker manufactures the LP Profile in standard shaft diameters ranging from 1/2” to 10” (12.7 mm to 254 mm). Because this is a precision machined seal, we can manufacture virtually any configuration.
Operation Type: Non-Flooded
Maximum Surface Speed: Up to 5,000 fpm (25 m/s)
Pressure Rating: 0 psi
Axial Movement: 0.020 inch (0.51 mm)
Eccentricity: 0.020 inch (0.51 mm)
Operating Temperature: -40° to 250 °F / -40° to 121 °C
Shaft Diameter: 0.492 to 10 inch (12.5 to 254 mm)
Bore Diameter: 0.886 to 11.575 inch (22.5 to 294 mm)
Seal Material: PTFE
O-Ring Material: FKM is standard. Alternates available
Due to the customized nature of this product, only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from 0.492” to 10” (12.5 mm to 254 mm).
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly. By keeping lubrication in and contaminants out, Parker’s ProTech™ bearing isolators provide reliable, two-way sealing protection of rotating equipment for extended bearing life. Labyrinth sealing technology applied to high performance materials allows the Parker ProTech LX Profile bearing isolator to operate far beyond the shaft speed limits of standard radial lip seals and avoids shaft wear. Because it is a precision-machined seal, costs can be eliminated on tooling charges, allowing retrofit of most shaft and bore combinations.
The non-contact design has virtually no torque consumption, will not wear or groove shafts, and allows for non-lubricated dry running. It also accommodates the greatest axial movement in the industry, reducing a major factor that causes labyrinth seal failure.
We can custom engineer solutions to meet exacting specifications for either new or retrofit applications. When used to replace seals during planned or unplanned rebuilds, the LX Profile lowers shaft cost due to liberal surface finish specifications.
DESIGN
The LX Profile shares design features with the LW Profile, such as a wrap-around geometry and enhanced rotor labyrinths for a more robust and aggressive labyrinth profile over standard designs. Enhanced internal oil splash grooves manage heavy oil splash in the bearing cavity. The LX profile, however, is designed for vertical up shaft mounts specifically and does not have an external drain port. An external O-ring on the outside diameter of the ProTech stator allows for easy seal installation, maintains a press fit in the seal housing, and provides a static seal against the bore for lubricant retention. The rotor uses an external O-ring to maintain a static press fit on the shaft. Since the rotor spins with the shaft, it will not wear, groove, or damage the shaft. This eliminates costs associated with having to recondition the sealing surface of the shaft.
The rotor and stator are assembled at Parker’s factory where they are permanently unitized, allowing for a one-piece installation. This unitized design also maintains the seal’s integrity by keeping high-pressure water spray, vibration or axial movement from separating or increasing the gap between the rotor and stator.
APPLICATIONS
The LX profile is an enhanced design for applications with aggressive oil splash and heavy contamination. The flange seats against the housing and acts as an installation guide by ensuring the seal alignment is correct. It is ideal for sealing and protecting the bearing housings of vertical up electric motors, pumps, mixers, gear boxes, blowers and custom equipment against heavy water spray and dry contaminants. The LW design is excellent for retaining grease and oil splash, however the oil level must be below the inboard oil drainback (non-flooded).
Total Eccentricity: 0.020” (0.51 mm)
Shaft speed: Up to 3,000 fpm (15 m/s). Contact Parker for speeds >3,000 fpm (15 m/s).
Maximum internal pressure: 0 psi (0 bar)
Axial Movement: 0.020” (0.51 mm) Special designs up to 0.070” (1.78 mm)
Shaft/Bore: Tolerances: ± 0.002” (± 0.05 mm)
The LX Profile shaft mounting positions and respective compatible lubrication types are:
MATERIALS
Stator & Rotor: ProTech uses advanced, proprietary PTFE compounds making it well suited for harsh environments, such as citric acids and strong caustics. This superior chemical resistance allows for the standardization of a single material within a plant, eliminating the cost associated with stocking duplicate sizes in expensive stainless steel or other exotic materials.
Characteristics of the various PTFE materials offered:
O-Rings: Come standard as FKM, but are also available in:
SIZE RANGE
Parker manufactures the LX Profile in standard shaft diameters ranging from 0.492” to 10” (12.5 mm to 254 mm). Because this is a precision machined seal, we can manufacture virtually any configuration.
Operation Type: Non-Flooded
Maximum Surface Speed: Up to 3,000 fpm (15 m/s)
Pressure Rating: 0 psi
Axial Movement: 0.020 inch (0.51 mm)
Eccentricity: 0.020 inch (0.51 mm)
Operating Temperature: -40° to 250 °F / -40° to 121 °C
Shaft Diameter: 0.492 to 10.000 inch (12.5 to 254 mm)
Bore Diameter: 1.043 to 11.575 inch (26.5 to 294 mm)
Seal Material: PTFE
O-Ring Material: FKM is standard. Alternates available.
Due to the customized nature of this product, only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from 0.492” to 10” (12.5 mm to 254 mm).
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly. By keeping lubrication in and contaminants out, Parker’s ProTech™ bearing isolators provide reliable protection of rotating equipment for extended bearing life – particularly in high pressure food and beverage wash down conditions. Labyrinth sealing technology applied to high performance materials allows Parker’s ProTech WD Profile bearing isolator to operate far beyond shaft speed limits of standard radial lip seals and avoid shaft wear.
The non-contact design has virtually no torque consumption and therefore will not wear or groove shafts, and allows for non-lubricated dry runs. It also accommodates the greatest axial movement in the industry, reducing the major factor that causes labyrinth seal leakage.
We can custom engineer solutions to meet exacting specifications for new or retrofit applications in most shaft and bore combinations. When used to replace seals during planned or unplanned rebuilds, the WD Profile lowers shaft cost due to liberal specifications. Costs can also be eliminated on tooling charges due to the fact that ProTech is a precision-machined seal.
DESIGN
An external O-ring on the outside diameter of the stator allows for easy seal installation, maintains a press fit in the seal housing, and provides a static seal against the bore for oil retention. The stator has a sophisticated series of grooves to retain oil splash, which has been tested by a major pump OEM and proved to be the most effective design for oil retention when compared to various competitor designs.
The rotor uses an external O-ring to maintain a static press fit on the shaft. Since the rotor spins with the shaft, it will not wear, groove, or damage the shaft. This eliminates costs associated with having to recondition the sealing surface of the shaft.
The rotor and stator are assembled at the Parker facility where they are permanently unitized, allowing for a one-piece installation. This unitized design also maintains the seal’s integrity by keeping high-pressure water spray, vibration or axial movement from separating or increasing the gap between the rotor and stator.
Additional features include:
Retains: Grease
Excludes: Heavy water spray and dry contaminants from bearing cavity
Equipment: Small disposable motors and equipment for the food processing industry; economical seal for
140 and 180 frame motors and other high volume OEM equipment requiring wash down protection where cost to upgrade the seal has been a deterrent.
MATERIALS
Stator & Rotor: ProTech uses proprietary PTFE compounds making it well suited for harsh environments, such as citric acids and strong caustics. This superior chemical resistance allows for the standardization of a single material within a plant, eliminating the need to stock duplicate sizes in expensive stainless steel or other exotic materials.
Characteristics of the various PTFE materials offered:
O-Rings: Come standard as FKM, but are also available in:
SHAFT MOUNTING POSITION: Compatible Lubrication types
SIZE RANGE
Parker manufactures the WD Profile in standard shaft diameters ranging from 0.492” to 10” (12.5 mm to 254 mm). Because this is a precision machined seal, we can manufacture virtually any configuration.
Operation Type: Non-Flooded
Maximum Surface Speed: Up to 7,000 fpm (35 m/s)
Pressure Rating: 0 psi
Axial Movement: 0.020 inch (0.51 mm)
Eccentricity: 0.020 inch (0.51 mm)
Operating Temperature: -40° to 400 °F / -40° to 204 °C
Shaft Diameter: 0.610 to 12.000 inch (15.5 to 304.8 mm)
Bore Diameter: 1.004 to 13.575 inch (25.5 to 344.8 mm)
Seal Material: Bronze, Stainless Steel, Carbon Steel, Other Alloys
O-Ring Material: FKM is standard. Alternates available
Due to the customized nature of this product, only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from 0.610” to 12” (15.5 mm to 305 mm). For a list of common sizes see Product Support tab.
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly. By keeping lubrication in and contaminants out, Parker’s bearing isolators provide reliable, two-way sealing protection of rotating equipment for extended bearing life and zero shaft wear. Labyrinth sealing technology applied to high performance materials allows Parker MILLENNIUM® ML bearing isolator to operate far beyond shaft speed and temperature limits of standard radial lip seals.
The non-contact design has virtually no torque consumption and therefore will not wear or groove shafts, and allows for non-lubricated dry running. It also accommodates the greatest axial movement in the industry, reducing the major factor that causes labyrinth seal leakage. We can custom engineer solutions to meet exacting specifications for either new or retrofit applications.
When used to replace seals during planned or unplanned rebuilds, the MILLENNIUM ML Profile lowers shaft cost due to liberal specifications. Costs can also be eliminated on tooling charges due to the fact that ProTech is a precision-machined seal.
DESIGN
The MILLENNIUM Profile is the first and only metallic isolator that is unitized without internal O-rings or locking rings. A proprietary unitization mechanism reduces potential leak paths while a non-wearing internal diffuser provides optimal spacing during installation and eliminates metallic dusting during start-up.
An external O-ring on the outside diameter of the stator allows for easy seal installation, maintains a press fit in the seal housing, and provides a static seal against the bore for oil retention. The stator has a sophisticated series of grooves to retain oil splash, which is proven to be the most effective design for oil retention when compared to various competitor designs.
The rotor uses an external O-ring to maintain a static press fit on the shaft. Since the rotor spins with the shaft, it will not wear, groove, or damage the shaft. This eliminates costs associated with having to recondition the sealing surface of the shaft.
The rotor and stator are assembled at the Parker facility where they are permanently unitized, allowing for a one-piece installation. This unitized design also maintains the seal’s integrity by keeping high-pressure water spray, vibration or axial movement from separating or increasing the gap between the rotor and stator.
Additional design features include:
APPLICATIONS
The MILLENNIUM ML Profile is our standard metallic design for non-flooded applications where a metallic seal is preferred and flange mounting is required. The flange seats against the housing and acts as an installation guide by ensuring the seal alignment is correct. It is ideal for sealing and protecting the bearing housings of electric motors, pumps, mixers, gear boxes, turbines, blowers and custom equipment against heavy water spray and dry contaminants. The ML design is excellent for retaining grease and oil splash, however the oil level must be below the inboard oil drainback of the seal (non-flooded). If external contamination is heavy in vertical up mounting position, Parker’s MILLENNIUM MX Profile may be a preferred design.
Total Eccentricity: 0.020” (0.51 mm)
Shaft Speed: Up to 7,000 fpm (35 m/s)
Maximum internal pressure: 0 psi (0 bar)
Axial Movement: 0.020” (0.51 mm). Special designs up to .100” (2.54 mm)
Shaft/Bore: Tolerances ±0.002” (±.05 mm). Special designs available
MATERIALS
Stator & Rotor: Available in various metallic materials, listed below.
O-Rings: Come standard as FKM, but are also available in:
The MILLENNIUM ML shaft mounting positions and respective compatible lubrication types are:
SIZE RANGE
Parker manufactures the MILLENNIUM ML profile in standard shaft diameters ranging from 0.610” to 12” (15.5mm to 305mm). Because this is a precision machined seal, we can manufacture virtually any configuration.
Operation Type: Non-Flooded
Maximum Surface Speed: Up to 3,000 fpm (15 m/s)
Pressure Rating: 0 psi
Axial Movement: .020 inch (0.51 mm)
Eccentricity: .020 inch (0.51 mm)
Operating Temperature: 40° to 250 °F / -40° to 121 °C
Shaft Diameter: .492 to 10.000 inch (12.5 to 254 mm)
Bore Diameter: .886 to 11.575 inch (22.5 to 294 mm)
Seal Material: TFE
O-Ring Material: KM is standard. Alternates available
Due to the customized nature of this product, only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from 0.492” to 10” (12.5 mm to 254 mm).
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly, but getting up and running again without necessity of an exhaustive tear down lessens the pain. Due to its split configuration, the SL Profile design can reduce downtime hours to minutes when seal replacement is required. By keeping lubrication in and contaminants out, Parker’s ProTech™ bearing isolators provide reliable, two-way sealing protection of rotating equipment for extended bearing life. Labyrinth sealing technology applied to high performance materials allows the Parker ProTech™ bearing isolators to operate far beyond the shaft speed limits of standard radial lip seals and avoid shaft wear. Because it is a precision-machined seal, costs can be eliminated on tooling charges, allowing retrofit of most shaft and bore combinations.
The non-contact design has virtually no torque consumption, will not wear or groove shafts, and allows for non-lubricated dry running. It also accommodates the greatest axial movement in the industry, reducing a major factor that causes labyrinth seal failure.
We can custom engineer solutions to meet exacting specifications for either new or retrofit applications.
When used to replace seals during planned or unplanned rebuilds, the SL Profile lowers shaft cost due to liberal surface finish specifications which require no wear sleeves or shaft refurbishment.
DESIGN
The SL Profile is split for easy installation. Once re-connected on the shaft, an external O-ring on the outside diameter of the ProTech stator allows for easy seal installation, maintains a press fit in the seal housing, and provides a static seal against the bore for lubricant retention. The stator has a sophisticated series of grooves to retain oil splash. On the shaft, the rotor uses an external O-ring to maintain a static press fit once the two halves are joined. Since the rotor spins with the shaft, it will not wear, groove, or damage the shaft.
APPLICATIONS
The SL profile is our split, standard design for non-flooded applications where the seal must be flange mounted. It is ideal for repairs and field retrofits where electric motors, pumps, mixers, gear boxes, blowers and custom equipment cannot easily be uncoupled or disassembled. The flange seats against the housing and acts as an installation guide by ensuring the seal alignment is correct. The SL design seals and protects the bearing housings against heavy water spray and dry contaminants. It is excellent for retaining grease and oil splash, however the oil level must be below the inboard oil drainback (non-flooded). In vertical down mounting positions the SL Profile may require a locking collar.
Total Eccentricity: 0.020” (.51 mm)
Shaft Speed: Up to 3,000 fpm (15 m/s). Contact factory for speed exceeding 3,000 fpm (15 m/s).
Maximum internal pressure: 0 psi (0 bar)
Axial Movement: 0.020” (0.51mm)
Shaft/Bore Tolerances ±0.002” (±0.05mm). Special designs available.
The SL Profile shaft mounting positions and respective compatible lubrication types are:
MATERIALS
Stator & Rotor: ProTech uses proprietary PTFE compounds making it well suited for harsh environments, such as citric acids and strong caustics. This superior chemical resistance allows for the standardization of a single material within a plant, eliminating the cost associated with stocking duplicate sizes in expensive stainless steel or other exotic materials.
Characteristics of the various PTFE materials offered:
O-Rings: Come standard as FKM, but are also available in:
SIZE RANGE
Parker manufactures the SL Profile in standard shaft diameters ranging from 0.492” to 10” (12.5 mm to 254 mm). Because this is a precision machined seal, we can manufacture virtually any configuration.
Operation Type: on-Flooded
Maximum Surface Speed: p to 3,000 fpm (15 m/s)
Pressure Rating: psi
Axial Movement: .020 inch (0.51 mm)
Eccentricity: .020 inch (0.51 mm)
Operating Temperature: -40° to 400 °F / -40° to 204 °C
Shaft Diameter: 0.610 to 10.000 inch (15.5 to 254 mm)
Bore Diameter: 1.319 to 11.575 inch (33.5 to 294 mm)
Seal Material: Bronze, Stainless Steel, Carbon Steel, Other Alloys
O-Ring Material: FKM is standard. Alternates available
Due to the customized nature of this product, only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from .610” to 12” (15.5 mm to 305 mm).
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly, but getting up and running again without necessity of an exhaustive tear down lessens the pain. Due to its split configuration, the MILLENNIUM® SM design can reduce downtime hours to minutes when seal replacement is required. By keeping lubrication in and contaminants out, Parker’s bearing isolators provide reliable, two-way sealing protection of rotating equipment for extended bearing life. Labyrinth sealing technology applied to high performance metallic materials allows the MILLENNIUM bearing isolators to operate far beyond the shaft speed limits of standard radial lip seals and avoid shaft wear. Because it is a precision-machined seal, costs can be eliminated on tooling charges, allowing retrofit of most shaft and bore combinations.
The non-contact design has virtually no torque consumption, will not wear or groove shafts, and allows for non-lubricated dry running. It also accommodates the greatest axial movement in the industry, reducing the major factor that causes labyrinth seal failure.
We can custom engineer solutions to meet exacting specifications for either new or retrofit applications.
When used to replace seals during planned or unplanned rebuilds, the MILLENNIUM SM lowers shaft cost due to liberal surface finish specifications which require no wear sleeves or shaft refurbishment.
DESIGN
The MILLENNIUM SM profile is split for easy installation. Once re-connected on the shaft, an external O-ring on the outside diameter of the stator allows for easy seal installation, maintains a press fit in the seal housing, and provides a static seal against the bore for lubricant retention. The stator has a sophisticated series of grooves to retain oil splash. On the shaft, the rotor uses an external O-ring to maintain a static press fit once the two halves are joined. Since the rotor spins with the shaft, it will not wear, groove, or damage the shaft.
APPLICATIONS
The MILLENNIUM SM profile is our standard, split metallic design for non-flooded applications where a split retrofit or replacement seal is preferred and flange mounting is required. The flange seats against the housing and acts as an installation guide by ensuring the seal alignment is correct. The SM design is excellent for retaining grease and oil splash, however the oil level must be below the inboard oil drainback of the seal (non-flooded).
Total Eccentricity: 0.020” (.51 mm)
Shaft Speed: Up to 7,000 fpm (35 m/s)
Maximum internal pressure: 0 psi (0 bar)
Axial Movement: 0.020” (0.51mm). Special designs up to 0.100” (2.54 mm)
Shaft/Bore: Tolerances ±0.002” (±0.05mm). Special designs available
MATERIALS
Stator & Rotor: Available in various metallic materials, listed below.
O-Rings: Come standard as FKM, but are also available in:
SIZE RANGE
Parker manufactures the MILLENNIUM SM profile in standard shaft diameters ranging from 0.610” to 12” (15.5 mm to 305 mm). Because this is a precision machined seal, we can manufacture virtually any configuration.
Operation Type: Non-Flooded
Maximum Surface Speed: Up to 7,000 fpm (35 m/s)
Pressure Rating: 0 psi
Axial Movement: 0.020 inch (0.51 mm)
Eccentricity: 0.020 inch (0.51 mm)
Operating Temperature: -40° to 400 °F / -40° to 204 °C
Shaft Diameter: 0.610 to 12.000 inch (15.5 to 304.8 mm)
Bore Diameter: 1.004 to 13.575 inch (25.5 to 344.8 mm)
Seal Material: Bronze, Stainless Steel, Carbon Steel, Other Alloys
O-Ring Material: FKM is standard. Alternates available
Due to the customized nature of this product, only a sampling of Parker’s shaft and bore diameters are shown. We can manufacture virtually any size in standard shaft diameters ranging from .610” to 12” (15.5 mm to 305 mm).
PERFORMANCE ADVANTAGES
Machine downtime due to bearing failure is costly. By keeping lubrication in and contaminants out, Parker’s bearing isolators provide reliable, two-way sealing protection of rotating equipment for extended bearing life. Labyrinth sealing technology applied to high performance materials allows Parker MILLENNIUM® MX Profile bearing isolator to operate far beyond shaft speed and temperature limits of standard radial lip seals and avoid shaft wear.
The non-contact design has virtually no torque consumption, will not wear or groove shafts, and allows for non-lubricated dry running. It also accommodates the greatest axial movement in the industry, reducing a major factor that causes labyrinth seal failure. We can custom engineer solutions to meet exacting specifications for either new or retrofit applications.
When used to replace seals during planned or unplanned rebuilds, the MILLENNIUM MX Profile lowers shaft cost due to liberal specifications. Costs can also be eliminated on tooling charges due to the fact that ProTech is a precision-machined seal.
DESIGN
The MILLENNIUM design is the first and only metallic isolator that is unitized without internal o-rings or locking rings. A proprietary unitization mechanism reduces potential leak paths while a non-wearing internal diffuser provides optimal spacing during installation and eliminates metallic dusting during start-up.
An external O-ring on the outside diameter of the stator allows for easy seal installation, maintains a press fit in the seal housing, and provides a static seal against the bore for oil retention. The stator has a sophisticated series of grooves to retain oil splash, which is proven to be the most effective design for oil retention when compared to various competitor designs.
The rotor uses an external O-ring to maintain a static press fit on the shaft. Since the rotor spins with the shaft, it will not wear, groove, or damage the shaft. This eliminates costs associated with having to recondition the sealing surface of the shaft.
The rotor and stator are assembled at the Parker facility where they are permanently unitized, allowing for a one-piece installation. This unitized design also maintains the seal’s integrity by keeping high-pressure water spray, vibration or axial movement from separating or increasing the gap between the rotor and stator.
Additional design features include:
APPLICATIONS
The MILLENNIUM MX Profile is our metallic design for vertical up, non-flooded applications where a metallic seal is preferred. It is ideal for sealing and protecting the bearing housings of electric motors, pumps, mixers, gear boxes, turbines, blowers and custom equipment against heavy water spray and dry contaminants. The MX design is excellent for retaining grease and oil splash, however the oil level must be below the inboard oil drainback of the seal (non-flooded). The MILLENNIUM MX is specifically designed to exclude contaminants in vertical up applications, and can run dry or with grease or oil lubrication.
Total Eccentricity: 0.020” (.51 mm)
Shaft Speed: Up to 7,000 fpm (35 m/s)
Maximum internal pressure: 0 psi (0 bar)
Axial Movement: 0.020” (0.51 mm). Special designs up to 0.100” (2.54 mm)
Shaft/Bore: Tolerances ±0.002” (±0.05 mm). Special designs available
MATERIALS
Stator & Rotor: Available in various metallic materials, listed below.
O-Rings: Come standard as FKM, but are also available in:
SIZE RANGE
Parker manufactures the MILLENNIUM MX profile in standard shaft diameters ranging from 0.610” to 12” (15.5 mm to 305 mm). Because this is a precision machined seal, we can manufacture virtually any configuration